In Our Element: How Do You Clean Copper Beryllium?

The composition and thickness of oxide films formed on the various copper beryllium alloys will vary somewhat depending on the beryllium content of the particular alloy, but the behavior of our copper beryllium Alloy 25 (C17200) is typical. In nominal nitrogen atmospheres (with or without hydrogen) the degree of BeO formation on heat treated ...

eCFR :: 29 CFR 1910.1024 -- Beryllium.

(I) Procedures for removing, laundering, storing, cleaning, repairing, and disposing of beryllium-contaminated personal protective clothing and equipment, including respirators. ( ii ) The …

Frequently Asked Questions: Beryllium and Beryllium …

Beryllium is a lightweight but extremely strong metal used in the aerospace, electronics, energy, telecommunications, medical, and defense industries. ... Examples of such situations include ventilation ductwork repairs, air cleaning equipment maintenance, or intermittent or periodic work operations (e.g., anode changing in pot rooms). ...

Chapter 296-850 WAC Beryllium

(10) Contaminated with beryllium and beryllium-contaminated. Contaminated with dust, fumes, mists, or solutions containing beryllium in concentrations greater than or equal to 0.1 percent by weight. (11) Dermal contact with beryllium. Skin exposure to: (a) Soluble beryllium compounds containing beryllium in concentrations greater than or

Copper Beryllium Alloys

Copper-beryllium alloys are available in two basic classes, shown in Table 1. High-strength copper beryllium is very strong and offers moderate to good conductivity. High-conductivity copper beryllium, on the other hand, features maximum con-ductivity and slightly lower strength levels. Table 1: Copper-Beryllium Alloys - Designations and UNS ...

Beryllium Mining | Processing Equipment | Flow Chart

Mozambique and a few other countries mine small amounts of beryl. The United States produces and exports large amounts of beryllium alloys and compounds, and thus is a net importer of ores, but a net exporter of finished beryllium products. Small amounts of beryllium become available from recycling of beryllium-containing scrap. Bertrandite Mining:

Copper Beryllium Wrought Alloys

Copper Beryllium Wrought Alloys Safety Data Sheet according to the Hazard Communication Standard (CFR29 1910.1200) HazCom 2012. ... compressed air for cleaning clothing, equipment, etc, is not recommended. Use only in well ventilated areas. Hygiene measures : Wash contaminated clothing before reuse. Always wash hands after handling the product.

California Code of Regulations, Title 8, Section 5205. Beryllium.

(D) The employer must ensure that no employee removes beryllium-contaminated personal protective clothing or equipment from the workplace, except for employees authorized to do so for the purposes of laundering, cleaning, maintaining or disposing of beryllium-contaminated personal protective clothing and equipment at an appropriate location or ...

Safety Practices for Working with Aluminum Beryllium …

The use of air cleaning equipment may be necessary to achieve the permissible emission. Tempered makeup air ... • Aluminum beryllium processing equipment and associated support systems (e.g. dust collectors, heat treat furnaces, coolant trays and reservoirs) should be cleaned on a regular basis to prevent the accumulation of any beryllium- ...

Health Efects Exposure Control Plan

Beryllium is a strong, lightweight metal frequently used in metal alloys because it is non-magneic and non- ... • Procedures for cleaning contaminated PPE and equipment. Employees who are exposed to beryllium at or above the OSHA Acion Level (0.1 µg/m3) for more than 30

Beryllium Compliance Guide -Personal Protective Equipment

The employer must ensure that no employee removes beryllium-contaminated personal protective clothing or equipment from the workplace, except for employees authorized to do so for the purposes of laundering, cleaning, maintaining or disposing of beryllium-contaminated personal protective clothing and equipment at an appropriate location or ...

Aqueous Cleaning for Precision Bearings and Beryllium.

parts requiring cleaning are precision instrument bearings and assemblies containing beryllium. The principal solvents used for this cleaning have been 1,1,2-Trichloro 1,2,2-trifluoroethane (CFC-113) and 1,1,1-Trichloroethane (MCF). The Center has begun modifying its many cleaning processes to use known alternatives for these solvents.

SAFETY DATA SHEET

Beryllium Oxide Ceramic TWA 0.00005 mg/m3 Inhalable fraction. Product Components Type Value Form Beryllium Oxide (CAS TWA 0.00005 mg/m3 Inhalable fraction. ) ... air cleaning equipment filter changes, maintenance, furnace tending, etc. Skin contact with this material may cause, in some sensitive individuals, an allergic dermal response ...

Beryllium Processing | Equipment, Flow, Cases

Most beryllium is used in metal alloys, which account for more than 70% of world consumption. Because beryllium is very light and has a high melting temperature, it is an ideal metal for use in the aerospace and defense industry, almost always alloyed with other metals.

1910.1024

Procedures for removing, laundering, storing, cleaning, repairing, and disposing of beryllium-contaminated personal protective clothing and equipment, including respirators. …

Safety Practices for Machining Copper Beryllium Alloys …

• Copper beryllium machining equipment and associated support systems (e.g., dust collectors, heat treat furnaces, ... • Wet cleaning and vacuuming are effective methods for cleaning machining and support equipment. • Rags, towels or wipes used to dry or wipe parts clean should not be allowed to dry and must be maintained in a

Beryllium Work Area Compliance Action Plan

H. A list of personal protective clothing and equipment required by the standard; and I. Procedures for removing, laundering, storing, cleaning, repairing, and disposing of beryllium-contaminated personal protective clothing and equipment, including respirators. NOTE: Resources in the Guide for Compliance website contains templates for

Working With Beryllium Copper

Working With Beryllium Copper 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER ... – Such equipment would only require cleaning per normal shop practice. – Equipment designated for this purpose shall be clearly labeled

Beryllium

Exposure Evaluation and Controls Exposure to beryllium via inhalation of airborne beryllium or dermal contact with beryllium-containing dust, fume, mist or solutions can cause health effects. The following resources provide information on exposure limits and analytical methods used to evaluate workers' beryllium exposure.

Preventing Beryllium Disease: Tips for Minimizing Exposure

This includes regular cleaning, inspection, and repair of equipment to prevent leaks, spills, or other malfunctions that could lead to increased beryllium exposure. In addition to these measures, employers should also provide appropriate personal protective equipment (PPE) to further minimize exposure.

Beryllium Worker Training Quiz INSERT COMPANY …

4. Prohibited cleaning methods include _____. a. Wet cleaning with soap, water, sponges, and mops b. HEPA vacuuming c. Wet floor scrubbers d. Dry sweeping, brushing, using compressed air . 5. Regarding personal protective equipment (PPE), workers must be able to demonstrate (mark all that apply): a. when and what kind of PPE is necessary b.

Beryllium (Be) Element: History, Properties, Uses, Toxicity, …

Beryllium is a toxic bivalent element that is steel gray in color, strong, and light in weight and is mostly utilized as a hardening agent in alloys. ... such as when rebuilding a furnace, maintaining or repairing air cleaning equipment, renovating a building, welding, etc. During routine hand-to-face activities such rubbing the nose or eyes ...

Beryllium Compliance Guide

A sufficient housekeeping program for beryllium may include a routine cleaning schedule and the use of effective cleaning methods to minimize exposure from accumulation of beryllium on surfaces. ... Any change in production processes, materials, equipment, personnel, work practices, or control methods results, or can reasonably be expected to ...

Safety Practices for Sanding, Grinding, Buffing

• Copper beryllium machining equipment and associated support systems (e.g., dust collectors, heat treat furnaces, coolant trays and reservoirs) should be cleaned on a regular basis to prevent the accumulation of copper beryllium containing materials. • The use of compressed air or brooms for cleaning dust must be prohibited.

Small Entity Compliance Guide for Beryllium in General …

Cleaning equipment must be handled and maintained in a manner that minimizes the reentry of beryllium into the workplace. HEPA-filtered vacuum equipment must be cleaned and …

Beryllium

Beryllium is a lightweight but extremely strong metal used in the aerospace, electronics, energy, telecommunications, medical, and defense industries. Beryllium-copper alloys are widely used …

Tips for Controlling Beryllium Exposure in Your Workplace

Wear a respirator and other personal protective equipment to work with or around beryllium; Clean equipment, working surfaces, and floors with high-efficiency particulate air (HEPA) vacuums, not compressed air; ... The person(s) cleaning the spill should, at the very least, wear a respirator. If the respirator is the sole means of protection, a ...

MATERIAL SAFETY DATA SHEET

Fax: (520) 573-9077 CHEMICAL FAMILY Beryllium Compound 24-HR. EMERGENCY ASSISTANCE Transportation Emergency Call Chemtrec at: PRODUCT SAFETY SERVICE ... rebuilding, maintenance or repair of air cleaning equipment, structural renovation, etc. Particulate depositing on hands, gloves, and clothing, can be transferred to the breathing zone and ...

Control Techniques For Beryllium Air Pollutants

GAS CLEANING EQUIPMENT FOR BERYLLIUM AND BERYLLIUM OXIDE MACHINE SHOPS Equipment Oil-mist collector Wet rotary cyclones Dry rotary cyclones Multiple (dry) cyclones Fabric filters Prefilter and HEPA filter Frequency of use Fairly common Fairly common Fairly common Frequent Fairly common Fairly common Location Initial Initial Initial Initul ...

Berylium Window Magnetic Field Laboratory Safety …

1. Broken Beryllium Window on an X-ray Detector or X-ray source. X-ray detectors and X-ray sources are typically equipped with a thin beryllium window (tens to hundreds of microns thick), which is mounted by the equipment manufacturer. 2. Broken Beryllium Window Under Vacuum: A beryllium window can rupture under vacuum due to an unanticipated over-